Technical data

Technical data with refrigerant R-407C (DX radiator )
WUC = upward blowing with liquid chilling
WDC = downward blowing with liquid chilling
Nominal condensing output at room temperature 24º C, 50 %, condensation temperature 45º C
Single-circuit units
Device type 020-1 030-1 035-1
Total output kW 8 11 15
Sensible output kW 6 9 12
Condensing output requirement kW 11 14 20
Compressors (hermetic) 400V-3ph-50Hz
Number 1 1 1
Power requirement kW 2,4 3,3 4,5
Centrifugal fans 230V-1Ph-50Hz direct-drive
Number 1 1 1
Air quantity m3/s 0,33 0,53 0,75
External pressure Pa 60 60 60
Motor output kW 0,35 0,35 0,35
Filters EU5
Number 1 1 1
Size: upward blowing 600x400 600x400 600x400
Size: downward blowing 600x400 600x400 600x400
After-heating 400V-3Ph-50Hz
Heating output kW 3 3 3
Number of elements 1 1 1

Number of steps

1 1 1
Humidification 400V-3Ph-50Hz
Humidification output kg 3,0 3,0 4,7
Connected load kW 2,2 2,23,4 3,4
Dimensions and weight
Width mm 760 760 760
Depth mm 650 650 650
Height mm 1920 1920 1920
Weight kg 160 160 170
Exhaust chamber height 500 mm
(to be added to height of unit, model WUC)
Connections
Humidifier mm 6 6 6
Drain mm 32 32 32
Unit´s electrical connected load 400V-3Ph-50Hz
Types A and E kW 2,8 3,7 5,0
Type B kW 5,8 6,7 8,0
Type C kW 5,0 5,9 8,4
Type D kW 8,0 8,9 11,4
A = chilling
B = chilling + electrical heating
C = chilling + humidification
D = chilling + heating + humidification + drying
E = water heating instead of electrical heating
Liquid chiller selections
WUC- and WDC units
Device type 020-1 030-1 035-1
Condensing output requirement kW 11 14 20
Liquid chillers (outdoor temperature 30°C, liquid temperature 37 / 42°C (nominal value), 35 % propylene glycol)
Alternative 1 CCSG 3-11-25-5 CCSG 5-11-32-6 CCSG 8-9-40-9
Noise level dB(A) at 10-m distance 45 45 45
Liquid flow l/s 0,6 0,9 1,2
Pressure drop kPa 22,9 36,1 33,6
Alternative 2 CCSG 3-14-25-5 CCSG 5-14-25-5 CCSG 6-14-40-11
Noise level dB(A) at 10-m distance 51 52 55
Liquid flow l/s 0,7 0,7 1,5
Pressure drop kPa 27,7 28,0 30,0