  • HEAT PUMP SOLUTION DESIGN AND IMPLEMENTATION
    Chillquick Thermo™ is a revolutionary series of heat pumps which enable flexibility and energy efficiency as never before. Two-way units both chill and heat. Chillquick Thermo™ series can fulfill all site needs up to 2000kW. Chillquick Thermo™ -heat pumps can be connected to the Service Next™ -service.
 

Chillquick Thermo™ Heat Pumps

The new Chillquick Thermo™ heat pumps offer both heating and cooling and they can achieve a significantly improved efficiency compared with traditional solutions.

The modular structure means that the heat pumps can be manufactured for the particular requirements of every customer. The system can contain several heat recovery, collection and cooling systems. If necessary, the heat can be utilized at several temperature levels. Active or passive cooling and heating can be implemented at the same time.


Cooling during springtime occurs directly from a ground well without using any compressors. In the summers, the condensate heat from the compressors is pumped back to the wells by means of the REC function. In the winter, the same heat is used as energy for the evaporating circuit. Hot water is produced in the superheat circuit by means of the SHE-function.


The units are available with optional COPtronic™-energy efficiency measurement and Kiotronic™-leak detection system. The whole system is monitored by the Service Next™ supervision service. Units are also connected in real-time to Chiller's Help Desk.





Chillquick Thermo™ -Heat Pump range



Chillquick Thermo™ H

  • Industry and renovating sites 

    (Heat recovery, heating and cooling)
  • Condensation also into district heating networks.
  • Heat production +60…+80 °C.


Chillquick Thermo™ M
  • Medium-sized buildings (district heating).
  • For cooling and heating.
  • Heat production +40…+65 °C.


Chillquick Thermo™ L
  • Small and medium-sized buildings 

    (district heating).
  • Heat production +30…+55 °C.






ServiceNext™solution for the management of cooling.
Read more


Leak detection system of refrigeration units.
Indication and reporting through the Service Next™ -service.


For accurate energy measurement of the cooling unit and heat pump.



Chillquick Thermo™ technology

The smaller Chillquick Thermo™ models (up to 40 kW) are single compressor solutions. The larger heat pumps are reliable dual or quad compressor dual-circuits. Thanks to the modular structure, the same unit can be fitted with an up to 800 l header tank and various pump and control valve solutions.

The unit is also very quiet thanks to the very small torque variation in the scroll compressor.

Each unit comes equipped with an electronic expansion valve, which, together with the advanced automated control feature, ensures that the unit runs in the most energy-efficient and operationally-reliable way in all conditions.
The Chillquick Thermo™ heat pumps use the R410A refrigerant developed for use in air conditioning and heat pumps, and they are always fully factory-tested.


Control automation for the Chillquick Thermo™

The control automation for the Chillquick Thermo™ works as a completely independent control system for the pump´s heating and cooling circuit or it can be connected to another building automation system. The automation technology optimises the machine start-up in accordance with every operational situation and need, and guarantees even temperatures across a building´s heating and cooling systems.

  • Control of heating and cooling
  • Optimisation and regulation of compressor start-ups
  • Automatic restarting after a power outage
  • Multifunctional shielding and warning functions
  • Daily and weekly timer
  • Controller available with Finnish/English display

Technical data Chillquick Thermo™ (10...40 kW)

Model CHT-5...12-1S-X-P1-P3-STD, type and selections are available from Chiller Oy´s sales engineers or from an authorized sales organization.


5-1 6-1 8-1 10-1 12-1
Heating cap. kW 14,8 19,4 25,8 34,4 38,5
Cap. adjusting 0;100% 0;100% 0;100% 0;100% 0;100%
Mains 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50
Power input kW 7,6 10,1 13,6 17,1 19,6
Running amps A 17,6 20,6 24,1 30,1 34,6
Precut-out fuse A (slow) 20 25 32 40 40
Nominal flows:




Cold side kg/s 0,77 1,00 1,31 1,79 1,97
Hot side kg/s 0,68 0,89 1,18 1,57 1,76
Refr. R410A kg 3,3 3,6 3,6 4 4,5
Dimensions:




Length mm 1240 1240 1240 1240 1240
Width mm 750 750 750 750 750
Height mm 1850 1850 1850 1850 1850



Technical data Chillquick Thermo™ (40...100 kW)

Model CHT-12...28-2D-X-P1-P3-STD, type and selections are available from Chiller Oy´s sales engineers or from an authorized sales organization.


12-2 16-2 20-2 24-2 28-2
Heating cap. kW 38,5 50,4 66,6 74,2 98,9
Cap. adjusting 0;50;100% 0;50;100% 0;50;100% 0;50;100% 0;50;100%
Mains 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50
Power input kW 19,8 25,8 33,5 37,5 52,0
Running amps A 35,1 43,1 57,2 67,2 88,4
Precut-out fuse A (slow) 50 63 80 80 100
Nominal flows:




Cold side kg/s 1,99 2,57 3,42 3,73 4,88
Hot side kg/s 1,76 2,31 3,05 3,39 4,52
Refr. R410A kg 7,2 7,2 8 9 11
Dimensions:




Length mm 1790 1790 1790 1790 1790
Width mm 750 750 750 750 750
Height mm 1850 1850 1850 1850 1850

 

Technical data Chillquick Thermo™ (100...300 kW)

Model CHT-32...100-4D-X-P1-P3-STD, type and selections are available from Chiller Oy´s sales engineers or from an authorized sales organization.


32-4 44-4 48-4 64-4 80-4 100-4
Heating cap. kW 98,2 128,2 149,9 201,8 259,8 307,2
Cap. adjusting 0;25;50;100% 0;25;50;100% 0;25;50;100% 0;25;50;100% 0;25;50;100% 0;25;50;100%
Mains 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50
Power input kW 52,6 67,6 77,0 105,0 128,0 151,5
Running amps A 89,3 114,9 138,4 174,4 224 255,2
Precut-out fuse A (slow) 100 125 160 200 250 315
Nominal flows:





Cold side kg/s 4,89 6,32 7,42 9,80 13,0 15,6
Hot side kg/s 4,49 5,86 6,86 9,21 11,9 14,1
Refr. R410A kg 12,6 18 18 30 34 36
Dimensions:





Length mm 2170 2170 2170 2170 2170 2170
Width mm 900 900 900 900 900 900
Height mm 1950 1950 1950 1950 1950 1950

 

  • Capacity by values 0/-3°C (30% etanol) and 44/50°C (water)
  • Power input: compressor and pumps P1 and P3
  • Exact selection data from sales engineer (on base of concrete project requirements)
  • Chiller Oy reserves right to make changes without prior notice!



Optional acessories

Optional acessories for the Chillquick Thermo™ heat pump

  • Header, pump, and valve modules
  • Heat exchanger and control modules
  • Superheat exhaust heat exchangers
  • Tailored header tanks
  • Warning signal via GSM modem
  • Connection to the building automation bus (Mod Bus TCP/IP)
  • Remote monitoring via the Internet and a mobile device or central hub
  • Soft starters
  • Sound dampening hood for the compressor
  • Special sound dampening in the frame structure

Brochure and technical data

Download Chillquick Thermo™ -materials >


Description of operations, activity diagram, and dimensions

Read more about the Selection Programme >